TestkingPDF HPE6-A66 dumps & HP Certification Sure Practice with 60 Questions [Q35-Q55]

Share

TestkingPDF  HPE6-A66 dumps & HP Certification Sure Practice with 60 Questions

New HPE6-A66 Exam Questions| Real HPE6-A66 Dumps


Understanding functional and technical aspects of Produce a detailed design specification document

The following will be asked from you in the HP HPE6-A66 dumps pdf:

  • Given the customer’srequirements, explain and justify the recommended solution.
  • Given a customer scenario for a simple campus environment, choose the appropriate componentsthat should be included in the BOM
  • Given the customer scenario and service level agreements, document the licensing and maintenance requirements
  • Given a customer scenario of a simple site environment, design and document the logical and physical network solutions
  • Given the customer requirementsfor a simple site environment determine the component details and document the high-level design

How to Prepare For Aruba Certified Design Associate Exam

Preparation Guide for Aruba Certified Design Associate Exam

Introduction

This exam validates you have a fundamental knowledge of an Aruba network design and know the Aruba product lines to help you design the network with the assistance of a senior designer. Candidate should know how to read a customer request and extract the information needed for a wired or wireless network. Candidate should know how to use VRF and IRIS. HP HPE6-A66 practice exams and HP HPE6-A66 practice test will help you to understand and memorize the concepts and detailed answers and solutions.

Candidate should give this exam who want:

  • To validate you understand the fundamentals of designing an Aruba Mobile First Platform
  • To advance your career as a certified professional
  • To position yourself as a trusted team member who can contribute to the design of enterprise-wide Aruba campus wired and wireless networks.

HP HPE6-A66 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Evaluate the customer requirements for a simple campus environment identify gaps per a gap analysis
  • Produce a detailed design specification document
Topic 2
  • Design and document the logical and physical network solutions
  • Simple site environment determine the component details and document the high-level design
Topic 3
  • Given an outline of a customer's needs for a simple campus environment determine the information required to create a solution
Topic 4
  • Translate the business needs of a simple campus environment into technical customer requirements
  • Select components based on the analysis results
Topic 5
  • Given the customer scenario and service level agreements, document the licensing and maintenance requirements
  • Plan and design an Aruba solution per customer requirements
Topic 6
  • Evaluate the requirements, and select the appropriate Aruba solution for the design
  • Choose the appropriate components that should be included in the BOM
Topic 7
  • Explain how a specific technology or solution would meet the customer's requirements
  • Recommend the solution to the customer
Topic 8
  • Requirements for a single-site campus environment design the high-level Aruba solution
Topic 9
  • Given the customer's requirements, explain and justify the recommended solution
  • Gather and analyze data, and document customer requirements

 

NEW QUESTION 35
NewRocket requires a wireless capacity design 30 Aruba 510 APs will be connected to each wiring closet using SmartRate connections. Wireless coverage needs to be provided even if a POE+ switch loses power Because of security concerns, wired video cameras were recently installed throughout the facility. There are 12 of these per floor. 6 per wiring closet. The cameras are 802.11n WiFi capable and have power injectors from which to draw power.
Based on the POE+ needs of the mentioned devices, which solution would meet the POE+ requirements while still providing a redundant and cost-effective Wi-Fi solution for the devices that require POE+ for Building 1, Floor 2?

  • A. Two 2930M 24-port POE+ switches
  • B. One 3810M 40G 8 HPE Smart Rate switch
  • C. One 2930M 48-port POE+ switch
  • D. Two 2930F 24-port POE+ switches

Answer: C

 

NEW QUESTION 36
A company has chosen an Aruba mobility controller solution for the redesign of their wireless network The design will have two 7205 controllers in a cluster for campus employees and a single VMC-50 virtual controller for remote access via a DMZ. A Mobility Master (MM) is used for centralized license and controller management. All controllers will minimally run ArubaOS 8 4 or later Currently the company has 1.000 employees. There are 30 branch offices that will use RAPs to connect to the DMZ controller. A peak of 100 users concurrently using the VIA client will also connect to the DMZ controller.
How many Aruba LIC-VIA licenses does the company need to purchase for this solution?

  • A. 0
  • B. 1
  • C. 1,030
  • D. 2

Answer: C

 

NEW QUESTION 37
A network architect wants to estimate the number of Aruba APs that will be needed Tor a new wireless design and determine the wireless coverage using VisualRF. The company requires a high-density design. The building has 200.000 square feet. How many APs should the network architect add to VisualRF in order to perform the coverage analysis?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 38
A network architect is doing a site survey for a new wireless design One concern the company has with the old wireless network is coverage. In some cases, APs would lose power and some employees in the network would lose wireless connectivity. The new design needs to prevent this issue from occurring. During the site survey, what are best practices to be followed in regards to the dBm signal level and the power of the AP to ensure adequate wireless coverage and minimal overlap of AP signals for the new design?

  • A. AP power at 100% and a measurement of -65 dBM on the measuring device
  • B. AP power at 75% and a measurement of -80 dBM on the measuring device
  • C. AP power at 50% and a measurement of -65 dBM on the measuring device
  • D. AP power at 75% and a measurement of -90 dBM on the measuring device

Answer: A

 

NEW QUESTION 39
A customer placed an order for an ArubaOS 5406R switch and plans to rack mount it in a wiring closet. The dimensions of the switch are 17.5 inches wide (44.45 cm), 6.9 inches high (17.5 cm), and 17.75 inches deep (45.1 cm). How many rack units should a customer plan for this switch?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 40
A network architect is redesigning the access layer in a data center for a customer. The access layer requires fixed-port switches that support VSF and data center features like L2 VXLAN and REST-API Which switching solution should the network architect recommend?

  • A. 3810M
  • B. 0
  • C. 1
  • D. 2930F

Answer: D

 

NEW QUESTION 41
A company is redesigning their wireless network and will be upgrading all devices to support the latest wireless standards. The company is not near any radar installations. In order to keep wireless NIC power levels as low as possible to reduce interference issues and to take advantage of radar frequency ranges, what IEEE standard should APs support?

  • A. S02.11V
  • B. 802.11 ax
  • C. 802.11r
  • D. S02.11h

Answer: B

 

NEW QUESTION 42
A wiring closet with a POE+ switch is 250 feet (76 meters) away from an AP on a building floor. The AP's smart-rate port is connected to a smart-rate port on the switch, which is capable of 10 Gbps. The cable type is Cat5e STP. What is the maximum speed that the customer can expect from the connected AP?

  • A. 10 Gbps
  • B. 5 Gbps
  • C. 2.5 Gbps
  • D. 1 Gbps

Answer: C

 

NEW QUESTION 43
Which two challenges do802.1ig barcode scanners present to a WLAN design? (Select two.)

  • A. implementing adequate security measures to ensure PCI compliance
  • B. determining the RF channel bandwidth consumed per Barcode scanner
  • C. roaming between APs
  • D. providing consistent performance on all available channels
  • E. encountering RF interference by devices

Answer: A,D

 

NEW QUESTION 44
A customer is purchasing Aruba 555 APs for a new wireless network. The APs will be pre-staged as campus APs (CAPs) and be managed by a controller solution During the pre-staging process, console access to the APs might be necessary Which console connection cable should the customer purchase for the 555 APs?

  • A. RJ-45
  • B. USB-A
  • C. RS-232
  • D. Micro-B USB

Answer: D

 

NEW QUESTION 45
A network architect is designing a new Wi-Fi solution for a customer The customer currently occupies a one-story building on a small campus. In one part of the building there is an auditorium, where the ceiling height and attenuation is different from the rest of the building. What should the network architect create in VisualRF to identify this difference when planning :ne APs?

  • A. Define the appropriate properties in the Building View
  • B. Spit the Building View into two Floorplan Views
  • C. Define the appropriate properties in the Network View
  • D. Create a Region in the Floorplan View

Answer: A

 

NEW QUESTION 46
A customer has a need to track traffic patterns and anomalies on a pair of ArubaOS-CX 8400 series switches. Which technology will the customer need to deploy for these switches?

  • A. Mobility First
  • B. Network Analysis Engine
  • C. NetEdit
  • D. 2 CiearPass

Answer: C

 

NEW QUESTION 47
A customer has over 100 access layer switches. The customer requires user authentication done via the Aruba Dynamic Segmentation feature. What components are required to implement this solution? (Select two.)

  • A. Active Directory server
  • B. Aruba mobility controller
  • C. Aruba APs
  • D. AirWave server
  • E. enterpnse authentication server

Answer: B,D

 

NEW QUESTION 48
A customer requires a campus core virtualization solution that supports a dual control and management planes, as well as active-active forwarding paths. Which solution would meet the customer's requirements?

  • A. VSX
  • B. Backplane stacking
  • C. VSF
  • D. Mesh stacking

Answer: B

 

NEW QUESTION 49
Which type of Aruba AP uses its radio as its back-haul connection?

  • A. Air Monitor (AM)
  • B. Mesh Porta
  • C. Mesh Point
  • D. Remote AP (RAP)

Answer: B

 

NEW QUESTION 50
A network architect has created two sites in IRIS and defined network devices for each site. From which window would a network architect connect the two sites together?

  • A. Start Page
  • B. Catalog
  • C. Site-1
  • D. Topology

Answer: C

 

NEW QUESTION 51
A network architect plans to use two ArubaOS 5406 switches in a wiring closet configured in a VSF domain The VSF link requires a 40 GDps connection Which SFP+ transceiver solutions would meet this requirement?

  • A. SFP
  • B. QSFP28
  • C. SmartRate
  • D. QSFP+ LC

Answer: C

 

NEW QUESTION 52
NewStellar has a main corporate campus in a business park with two adjacent buildings that are 150 feet apart (46 meters). This is an open campus with no obstructions between the two buildings Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total, which results in a total of 338,100 feet (31,410 square meters) for the entire building space. The ceiling for each floor is 12 feet (3.6 meters) high with a drop-down ceiling at 10 feet (3 meters) The network architect has given one floor to analyze. Building 1 Floor 2, shown in the attached exhibit.
This floor has a central main corridor with washrooms, stairs, elevators and supply, and network cabinets. There are cubicles around the perimeter of the floor. The central part main corridor's dimensions contain 9,350 square feet (870 square meters).
The company has determined that Wi-Fi coverage will not include the central area of each floor, which includes the washrooms, stairs, elevators and supply and network cabinets. Based on a capacity design, approximately how many APs should a network architect add to each floor to plan the design in VisuaiRF?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

 

NEW QUESTION 53
A company has two buildings on a campus that are approximately 700 feet (214 meters) apart with a clear line of site. No fiber exists between the buildings; however, there is a need for connecting the networks in the buildings together. The connection between the two buildings will need to support peak rates over 1 Gbps.
Which solution should the company choose that will meet their requirements as well as being cost-effective?

  • A. Two outdoor AP 510s
  • B. Multi-mode fiber between campus switches
  • C. Two outdoor AP 367s
  • D. Two outdoor AP 387s

Answer: C

 

NEW QUESTION 54
A network architect is creating a new wireless solution for a customer. Wireless coverage is required throughout all four floors of two buildings on the same campus. Dynamic RF capabilities, including AirMatch, are required. Seamless roaming is required within and between the two buildings. Each floor will have approximately 20 APs and 6 external APs are required for connectivity between the two buildings.

  • A. Given this information, which Aruba solution would be the most cost-effective while still meeting the customer's requirements? O An IAP cluster per floor
  • B. Two 7030 mobility controllers in a cluster
  • C. A standalone 7008 controller per floor
  • D. Two 7205 mobility controllers in a cluster

Answer: A

 

NEW QUESTION 55
......

HPE6-A66 Braindumps – HPE6-A66 Questions to Get Better Grades: https://www.testkingpdf.com/HPE6-A66-testking-pdf-torrent.html

Get New HPE6-A66 Certification – Valid Exam Dumps Questions: https://drive.google.com/open?id=1fb7cVGPYT428O-spUJKVzSwrAcaftbF2