The Huawei H19-371_V1.0-ENU (HCS-Pre-sales-Digital Power V1.0) Certification Exam is a comprehensive certification exam designed to test the pre-sales technical capabilities of candidates in the digital power domain. The exam covers a wide range of topics related to digital power technology and product solutions, and it is a great way for professionals to enhance their skills in digital power pre-sales. The certification validates the candidate's knowledge and expertise in the field, and it provides a competitive advantage in the job market.


The Huawei H19-371_V1.0-ENU (HCS-Pre-sales-Digital Power V1.0) Certification Exam is a professional certification exam that is designed to validate the skills and knowledge of individuals around digital power pre-sales. This exam is specifically tailored for those individuals that are looking to pursue a career in the digital power industry and want to demonstrate their technical expertise to potential employers.

 

NEW QUESTION # 290
The row-level chilled water intelligent temperature control product NetCol 5000-C032H adopts the form of running pipes ( )

  • A. Up the tube
  • B. Pipe up and down
  • C. Down the tube
  • D. Side run.

Answer: C


NEW QUESTION # 291
Which of the following statements about micromodules is true? ( )

  • A. ECC800 can access no more than 4 external gates
  • B. ECC800 can provide SNMP northbound interface
  • C. ECC800 can connect no more than 4 cameras
  • D. ECC800 can be connected to iBattery battery management system

Answer: A,B,C,D


NEW QUESTION # 292
The minimum floor height of the computer room required by FusionModule2000 is 2.6 meters.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 293
The bypass module of UPS5000-E-200K is the same as that of UPS5000-E-400K.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 294
The system efficiency of the UPS5000-E-75K half-height cabinet modular UPS is also 96% ( )

  • A. True
  • B. False

Answer: A


NEW QUESTION # 295
The FusionModule2000 localized power distribution cabinet has two input switches of single-channel MCCB and ATS.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 296
What is the maximum power of the IT cabinet of FusionModule500 & FusionModule800?

  • A. 7KVA
  • B. 3KVA
  • C. 9KVA
  • D. 5KVA

Answer: A


NEW QUESTION # 297
What are the input methods supported by Huawei Magic Box power supply?

  • A. Solar energy
  • B. Mains
  • C. Oil engine
  • D. battery

Answer: A,B,C,D


NEW QUESTION # 298
UPS5000-A can significantly reduce the harmonic pollution to the power grid. In the case of linear full load, the input current waveform distortion THDi is

  • A. 0.05
  • B. 0.01
  • C. 0.03
  • D. 0.02

Answer: C


NEW QUESTION # 299
Huawei iManager NetEco6000 can be accessed by Huawei's ( ) system

  • A. XXXX
  • B. esight
  • C. XXX

Answer: B


NEW QUESTION # 300
The NetEco management system can provide the power distribution topology map function, which can realize the monitoring of the whole power distribution link from the mains introduction to the end of the rPDU.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 301
In UPS5000S, the adjustable range of the number of battery cells in a single group is

  • A. Sections 30 to 48
  • B. Sections 30 to 46
  • C. Sections 30 to 42
  • D. Sections 30 to 44

Answer: A


NEW QUESTION # 302
The description of the bypass overload capacity of UPS5000-E is correct ( )

  • A. 1000% overload for 100ms
  • B. 125% overload for 60 minutes
  • C. 125% overload for 10 minutes
  • D. 135% long-term overload

Answer: D


NEW QUESTION # 303
The NetEco management system supports the function of user decentralization and domain division, so that different operation and maintenance personnel can only view the devices they manage. For example, by assigning permissions, an operation and maintenance personnel can only view the equipment information of the computer rooms of several outlets.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 304
UPS2000-G has the function of grading power off. When overloaded, the secondary load is turned off to eliminate the overload and ensure the quality of power supply. When the power is off, the secondary load is turned off to prolong the backup time of the important load.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 305
Huawei Netcol air-cooled air conditioner requires low temperature components when the outdoor temperature is lower than -20"C ( )

  • A. True
  • B. False

Answer: A


NEW QUESTION # 306
What is the thickness of the insulation material of the FusionModule1000A V2R3 version?

  • A. 120mm
  • B. 40mm
  • C. 60mm
  • D. 100mm

Answer: D


NEW QUESTION # 307
Compared with the fixed frequency structure, the advantages of using the DC frequency conversion structure for air-cooled temperature control products are ( )

  • A. Continuous cooling, the temperature fluctuation of the equipment room is small.
  • B. On-demand cooling, part-load more energy efficient
  • C. Reduce the number of compressor starts and stops, high reliability
  • D. Reduce the starting current, less impact on the grid

Answer: A,B,C,D


NEW QUESTION # 308
Which of the following alarm functions does the PDU8000 precision power distribution cabinet branch circuit have:

  • A. Branch overload
  • B. Current high threshold crossing alarm
  • C. Over frequency alarm
  • D. High current impact alarm
  • E. Over voltage alarm

Answer: A,B,C,D,E


NEW QUESTION # 309
UPS products such as APM and NXR need to be derated when the temperature is 30 degrees, and UPS5000-E does not need to be derated when the temperature is below 40 degrees.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 310
For large-scale data center power distribution rooms, when configuring upper air conditioners, the elements for selecting hood air supply and air duct air supply mainly include ( ). (Multiple choices)

  • A. Air supply distance
  • B. Air supply direction
  • C. Cost
  • D. Engineering complexity
  • E. Floor height

Answer: A,B,C,D,E


NEW QUESTION # 311
Which of the following statements about micromodules is true? (multiple choice)

  • A. ECC800 can access no more than 4 external gates
  • B. ECC800 can be connected to the CIM
  • C. ECC800 can connect no more than 4 cameras
  • D. ECC800 can provide SNMP northbound interface for free
  • E. ECC800 can be customized to access third-party equipment

Answer: A,B,C,D,E


NEW QUESTION # 312
......